Medtronic Presents U.S. Pivotal Trial Data for MiniMed™ 780G Advanced Hybrid Closed Loop System with Automated Correction Bolus Feature

Share

Data from Two Key Clinical Trials of the Next-Generation Medtronic Automated Insulin Pump Demonstrates Positive Results for Patients with Type 1 Diabetes

DUBLIN, June 12, 2020 (GLOBE NEWSWIRE) -- Medtronic plc (NYSE:MDT), the global leader in medical technology, today presented results from its U.S. pivotal trial of its investigational MiniMed™ 780G Advanced Hybrid Closed Loop (AHCL) system at the virtual 80th Scientific Sessions of the American Diabetes Association (ADA). The MiniMed 780G system, which features a default target of 100mg/dL (with the option of 120mg/dL), programmable insulin action time from two to eight hours, and automatic corrections every five minutes, met all study endpoints and demonstrated high user satisfaction across the studies being presented today at the conference.

Results of the 90-day at home U.S. pivotal trial, studying adults and adolescents aged 14-75 years old, show the trial successfully met both safety and glycemic endpoints and demonstrated no occurrences of severe adverse events. The trial results include:

  • No severe hypoglycemia and diabetic ketoacidosis
  • Average A1C of 7.0%
  • Overall Time in Range (defined as 70-180 mg/dL) of 75%, with overall Time Below Range (defined as less than 70 mg/dL) of 1.8%
  • Overnight Time in Range of 82%, with overnight Time Below Range of 1.5%
  • Autocorrection contributing to 22% of all bolus insulin
  • Participants being in SmartGuard™ (closed loop) 95% of the time
  • Mean sensor glucose (SG) of 148 mg/dL overall, and 144 mg/dL at the default 100mg/dl target

Results from a study questionnaire also demonstrated high user satisfaction with 96% indicating it was easy to use. System requests for fingerstick blood sugars were also reduced by 46% when compared to the MiniMed™ 670G system.

Lastly, the lower target glucose and active insulin time (AIT) settings substantially improved Time in Range, without increasing hypoglycemia. Time in Range increased to 76%, with a 100 mg/dL target and AIT of two to three hours and reached 79% when AIT was set to two hours. Results across all pump settings exceeded ADA and ATTD international clinical consensus Time in Range guidelines.

SettingOverall: 

Time in Range 
Daytime: 

Time in Range 
Overnight: 

Time in Range 
100 mg/dL default target 2-3 hour active insulin time (AIT)76%74%84%
2 hour AIT79%76%87%

“The results of the study are exciting and are a welcome addition to what we have seen with other advancements in automated insulin delivery systems. Most notable is the additional target glucose level of 100 mg/dL — which will be lower than the other commercially available devices in this category and likely contributed to the demonstrated improvements in study outcomes, namely Time in Range and A1C,” said Dr. Anders Carlson, medical director of the Park Nicollet International Diabetes Center (IDC) in Minneapolis, Minn. and investigator of the study. “We often hear from our patients about wanting lower glucose target settings, and there is certainly a desire to see that represented more in the current marketplace. I’m pleased to see this next generation closed loop system continuing to improve in that direction.”

Data from a second, randomized cross-over clinical trial based in New Zealand studied a more challenging patient group, including those with less-controlled diabetes and a younger patient population of children as young as seven years old, was also presented at the meeting. The results demonstrated improved outcomes for those on the Medtronic AHCL system when compared to a predictive low-glucose management (PLGM) algorithm, even for this patient group which entered the trial at a low baseline. The results included:

  • A 13 point overall improvement in Time in Range to 70.4%
  • A 0.4% overall decrease in Time Below Range (70mg/dL) to 2.1%
  • A 16% improvement in Time in Range overnight, due in large part to a 12% reduction in hyperglycemia
  • A 13.0% improvement in Time in Range to 70.2% at the default 100mg/dl target
  • Autocorrection contributing to 21% of all bolus insulin
  • Participants being in SmartGuard (closed loop) 95% of the time
  • Mean SG improvement of 10 mg/dL overall

The study met primary endpoints (increasing overall Time in Range), as well as secondary endpoints (decreasing overall time above and below range). Patients also reported through a study questionnaire being highly satisfied with their experience overall, with 95% agreeing that the system was easy to use and 85% agreeing that the system improved their quality of life.

“We wanted to design a system that further simplifies diabetes management and provides an extra layer of protection for the times one may forget a pre-meal bolus or miscalculate their carbohydrates,” said Robert Vigersky, M.D., chief medical officer for the Diabetes Group at Medtronic. “The combination of these two study findings, across a broad spectrum of patients at various levels of glucose control, are promising — they demonstrate that the smart automation featured in this next-generation system has tremendous potential for meaningfully reducing burden and enhancing quality of life.”

The investigational MiniMed 780G system is designed to automate the delivery of both basal insulin and correction boluses every five minutes to help people with diabetes avoid highs and lows with greater ease. Bluetooth® connectivity will also enable real-time monitoring of glucose levels and trends on smartphones by both the user and their care partners. Data from the pivotal study will be submitted as part of a future Premarket Approval (PMA) application to the U. S. Food and Drug Administration (FDA) for commercial approval of the MiniMed 780G system in the U.S. In the United States, the MiniMed 780G system is investigational use only, and not approved for sale or distribution. The MiniMed 780G system received CE(Conformité Européenne) Markingin June 2020.

The findings outlined above will be shared at the 80th Scientific Sessions of the American Diabetes Association virtual meeting, June 12-16, 2020:

Other data on the AHCL system at the 80th Scientific Sessions of the American Diabetes Association virtual meeting include:

About the Diabetes Group at Medtronic(www.medtronicdiabetes.com)
Medtronic is working together with the global community to change the way people manage diabetes. The company aims to transform diabetes care by expanding access, integrating care and improving outcomes, so people living with diabetes can enjoy greater freedom and better health.

About Medtronic
Medtronic plc (www.medtronic.com), headquartered in Dublin, Ireland, is among the world's largest medical technology, services and solutions companies - alleviating pain, restoring health and extending life for millions of people around the world. Medtronic employs more than 90,000 people worldwide, serving physicians, hospitals and patients in more than 150 countries. The company is focused on collaborating with stakeholders around the world to take healthcare Further, Together.

Any forward-looking statements are subject to risks and uncertainties such as those described in Medtronic's periodic reports on file with the Securities and Exchange Commission. Actual results may differ materially from anticipated results.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Medtronic is under license.

-end-

Kendra Cassillo
Public Relations
+1-818-576-5611

Ryan Weispfenning
Investor Relations
+1-763-505-4626

To view this piece of content from www.globenewswire.com, please give your consent at the top of this page.

About GlobeNewswire by notified

GlobeNewswire by notified
GlobeNewswire by notified
One Liberty Plaza - 165 Broadway
NY 10006 New York

https://notified.com

GlobeNewswire by notified is one of the world's largest newswire distribution networks, specializing in the delivery of corporate press releases financial disclosures and multimedia content to the media, investment community, individual investors and the general public.

Subscribe to releases from GlobeNewswire by notified

Subscribe to all the latest releases from GlobeNewswire by notified by registering your e-mail address below. You can unsubscribe at any time.

Latest releases from GlobeNewswire by notified

Iveco Group signs a 150 million euro term loan facility with Cassa Depositi e Prestiti to support investments in research, development and innovation11.6.2024 12:00:00 CEST | Press release

Turin, 11th June 2024. Iveco Group N.V. (EXM: IVG), a global automotive leader active in the Commercial & Specialty Vehicles, Powertrain and related Financial Services arenas, has successfully signed a term loan facility of 150 million euros with Cassa Depositi e Prestiti (CDP), for the creation of new projects in Italy dedicated to research, development and innovation. In detail, through the resources made available by CDP, Iveco Group will develop innovative technologies and architectures in the field of electric propulsion and further develop solutions for autonomous driving, digitalisation and vehicle connectivity aimed at increasing efficiency, safety, driving comfort and productivity. The financed investments, which will have a 5-year amortising profile, will be made by Iveco Group in Italy by the end of 2025. Iveco Group N.V. (EXM: IVG) is the home of unique people and brands that power your business and mission to advance a more sustainable society. The eight brands are each a

DSV, 1115 - SHARE BUYBACK IN DSV A/S11.6.2024 11:22:17 CEST | Press release

Company Announcement No. 1115 On 24 April 2024, we initiated a share buyback programme, as described in Company Announcement No. 1104. According to the programme, the company will in the period from 24 April 2024 until 23 July 2024 purchase own shares up to a maximum value of DKK 1,000 million, and no more than 1,700,000 shares, corresponding to 0.79% of the share capital at commencement of the programme. The programme has been implemented in accordance with Regulation No. 596/2014 of the European Parliament and Council of 16 April 2014 (“MAR”) (save for the rules on share buyback programmes set out in MAR article 5) and the Commission Delegated Regulation (EU) 2016/1052, also referred to as the Safe Harbour rules. Trading dayNumber of shares bought backAverage transaction priceAmount DKKAccumulated trading for days 1-25478,1001,023.01489,100,86026:3 June 20247,0001,050.597,354,13027:4 June 20245,0001,055.705,278,50028:6 June20243,0001,096.273,288,81029:7 June 20244,0001,106.174,424,68

Landsbankinn hf.: Offering of covered bonds11.6.2024 11:16:36 CEST | Press release

Landsbankinn will offer covered bonds for sale via auction held on Thursday 13 June at 15:00. An inflation-linked series, LBANK CBI 30, will be offered for sale. In connection with the auction, a covered bond exchange offering will take place, where holders of the inflation-linked series LBANK CBI 24 can sell the covered bonds in the series against covered bonds bought in the above-mentioned auction. The clean price of the bonds is predefined at 99,594. Expected settlement date is 20 June 2024. Covered bonds issued by Landsbankinn are rated A+ with stable outlook by S&P Global Ratings. Landsbankinn Capital Markets will manage the auction. For further information, please call +354 410 7330 or email verdbrefamidlun@landsbankinn.is.

Relay42 unlocks customer intelligence with a new insights and reporting module, powered by Amazon QuickSight11.6.2024 11:00:00 CEST | Press release

AMSTERDAM, June 11, 2024 (GLOBE NEWSWIRE) -- Relay42, a leading European Customer Data Platform (CDP), is leveraging Amazon QuickSight to power its new real-time customer intelligence, reporting, and dashboard module. Harnessing the breadth and quality of customer data, the new Insights module empowers marketing teams to dive deep into customer behaviors and gain invaluable insights into the performance of their marketing programs across all online, offline, paid, and owned marketing channels. Preview of the Relay42 Insights module, in pre-beta version Key capabilities of the Relay42 Insights module include: Deep insights into customer behaviors: With the Relay42 Insights module, marketers can ask unlimited questions about their data and gain a deeper understanding of how to serve their customers more effectively. Simplicity with AI-powered querying: Marketers can use artificial intelligence to query their data using natural language search, reducing the reliance on data scientists. Us

Metasphere Labs Announces X Spaces Event on the Topic of Green Bitcoin Mining and Sound Money for Sustainability11.6.2024 10:30:00 CEST | Press release

VANCOUVER, British Columbia, June 11, 2024 (GLOBE NEWSWIRE) -- Metasphere Labs Inc. (formerly Looking Glass Labs Ltd., "Metasphere Labs" or the "Company") (Cboe Canada: LABZ) (OTC: LABZF) (FRA: H1N) is thrilled to announce an engaging Twitter Spaces event on Green Bitcoin mining, energy markets, and sustainability on July 3, 2024 at 2 p.m. ET. Follow us on X at MetasphereLabs for updates and to join the event. What We'll Discuss Bitcoin Mining Basics: Understand the fundamentals of Bitcoin mining.Energy Market Dynamics: Explore how Bitcoin mining interacts with energy markets.Sustainable Innovations: Learn about our efforts to promote sustainability in Bitcoin mining.Sound Money: Discover how tamper-proof currency can enhance stability.Efficient Payment Rails: See how fast, neutral payment systems support humanitarian projects.Carbon Footprint: Compare Bitcoin's environmental impact with traditional banking. "We're excited to host this event and dive into the critical topics of Bitcoin

World GlobeA line styled icon from Orion Icon Library.HiddenA line styled icon from Orion Icon Library.Eye